Produktbeskrivelse
|
Brocade 16Gb/28 SAN Switch Power Pack+ for BladeSystem c-Class - switch - 28 porte - Administreret - plug-in modul
|
Enhedstype
|
Switch - 28 porte - Administreret
|
Pakningstype
|
Plug-in modul
|
Undertype
|
Fibre Channel
|
Porte
|
16 x 16 Gb Fiberkanal (intern) + 12 x 16Gb Fibre Channel
|
Præstation
|
Samlet båndbredde: 896 Gbps
|
Protokol til fjernadministration
|
SNMP, Telnet, HTTP, SMI-S
|
Egenskaber
|
Fuld dupleksmodus
|
Dimensioner (B x D x H)
|
26.85 cm x 19.28 cm x 2.79 cm
|
Vægt
|
1.5 kg
|
Producentgaranti
|
1 års garanti
|
Produktdatablad |
|
Enhedstype |
Switch - 28 porte - Administreret |
Pakningstype |
Plug-in modul |
Undertype |
Fibre Channel |
Porte |
16 x 16 Gb Fiberkanal (intern) + 12 x 16Gb Fibre Channel |
Præstation |
Samlet båndbredde: 896 Gbps |
Fiberkanal |
FC-AL-2, FC-DA, FC-FLA, FC-FS, FC-GS-4, FC-PI, FC-PLDA, FC-SB-3, FC-SW-3, FC-Tape, FC-VI, FC-BB-2, FCP-2, FC-PI-2, FC-BB-3, FC-FS-2, FC-GS-5, FC-SW-4, FC-LS, FC-MI-2, FC-PI-4, FC-IFR |
Protokol til fjernadministration |
SNMP, Telnet, HTTP, SMI-S |
Egenskaber |
Fuld dupleksmodus |
Interface |
12 x 16Gb Fibre Channel SFP+ |
Overensstemmelsesstandarder |
FCC Klasse A certificeret, CISPR 22 Klasse A, BSMI CNS 13438 Class A, EN 60950, NEMKO, VCCI Klasse A ITE, EN55022 Klasse A, UL 60950, CSA 22.2 No. 60950, AS/NZ 3548 Class A, EMC, FCC CFR47 Part 15 B, LVD |
Bredde |
26.85 cm |
Dybde |
19.28 cm |
Højde |
2.79 cm |
Vægt |
1.5 kg |
Service & Support |
Begrænset garanti - reservedele og arbejdskraft - 1 år - on-site |
Min. driftstemperatur |
10 °C |
Maks. driftstemperatur |
35 °C |
Fugtighedsgrad ved brug |
10 - 90 % (ikke-kondenserende) |
Min. lagertemperatur |
-30 °C |
Maks. Opbevaringstemperatur |
60 °C |
Lagerfugtighedsgrad |
5 - 95 % (ikke-kondenserende) |
Are you looking for a higher performance embedded Fiber Channel switch option for your HP BladeSystem c-Class enclosure? The Brocade 16Gb SAN Switch for HP BladeSystem c-Class represents the next generation of embedded Fiber Channel switches with 16 Gb/s performance. It hot-plugs into the back of the HP BladeSystem c-Class Enclosure and its integrated design frees up rack space, enables shared power and cooling, and reduces cabling and small form-factor pluggables. Enhanced trunking support with external switches provides higher bandwidth to enable demanding applications and high density server virtualization. In addition, the 16 or 28 auto-sensing ports support lower bandwidth components for investment protection and an upgrade license enables customers to 'pay as they grow'. The Brocade 16Gb SAN Switch saves space and cost, simplifies the SAN environment, enables easier deployment and management and delivers the performance required for higher throughput applications.